You are in:Home/Publications/Reliable Estimation for Health Index of Transformer Oil Based on Novel Combined Predictive Maintenance Techniques

Dr. mohamed badawi ahmed :: Publications:

Title:
Reliable Estimation for Health Index of Transformer Oil Based on Novel Combined Predictive Maintenance Techniques
Authors: Mohamed Badawi; Shimaa A. Ibrahim; Diaa-Eldin A. Mansour; Adel A. El-Faraskoury; Sayed A. Ward; Karar Mahmoud; Matti Lehtonen
Year: 2022
Keywords: Not Available
Journal: IEEE access
Volume: 10
Issue: Not Available
Pages: 25954 - 25972
Publisher: IEEE
Local/International: International
Paper Link:
Full paper Not Available
Supplementary materials Not Available
Abstract:

Transformer oil insulation condition may be deteriorated due to electrical and thermal faults, which may lead to transformer failure and system outage. In this regard, the first part of this paper presents comprehensive maintenance for power transformers aiming to diagnose transformer faults more accurately. Specifically, it aims to identify incipient faults in power transformers using what is known as dissolved gas analysis (DGA) with a new proposed integrated method. This proposed method for DGA is implemented based on the integration among the results of five different DGA techniques; 1) conditional probability, 2) clustering, 3) Duval triangle, 4) Roger’s four ratios refined, and 5) artificial neural network. Accordingly, this proposed integrated DGA method could improve the overall accuracy by 93.6% compared to the existing DGA techniques. In addition, the second part used for predictive maintenance is based on determining the health index for five new transformers and an aged power transformer (66/11 kV, 40 MVA) filled with NYTRO 10XN oil by evaluating the breakdown voltage, DGA, moisture content, and acidity for the oil. In the breakdown voltage test, two practical types of transformer oil; NYTRO 10XN and HyVolt III alongside their mixtures are estimated and compared. In addition, aged oil samples extracted from a real case study in-service transformer during operation with different aged durations; 9, 10, 11, 12, and 13 years, are tested for breakdown voltage, and then compared with fresh oil samples. For DGA, a temperature rise test is performed on the five new transformers with a comparison between dissolved gases before and after the temperature rise. In addition, winding resistance is measured after the temperature rise. Also, acidity and moisture are measured for oils extracted from the new five transformers and from the 13-year in-service transformer for studying their health index. The health index of the transformer insulation system is examined usin...

Google ScholarAcdemia.eduResearch GateLinkedinFacebookTwitterGoogle PlusYoutubeWordpressInstagramMendeleyZoteroEvernoteORCIDScopus